046 9020 625
Sale

G.A.S. Intelligent Humidity Controller for SonicAir Pro Humidifier

225.00 was €290.00
1 left in stock
The GAS Intelligent Humidity Controller efficiently manages humidity levels in your grow room, promoting faster growth and healthier plants. Air temperature and humidity influence Vapour Pressure Deficit (VPD), which determines the air's "drying" capacity.

Out of stock

Description

G.A.S. Intelligent Humidity Controller for SonicAir Pro Humidifier

The GAS Intelligent Humidity Controller efficiently manages humidity levels in your grow room, promoting faster growth and healthier plants. Air temperature and humidity influence Vapour Pressure Deficit (VPD), which determines the air's "drying" capacity. To maximize plant growth, humidity must align with the air temperature and growth stage. Until now, optimizing VPD in grow spaces has been challenging. The Intelligent Humidity Controller resolves this by directly regulating a G.A.S SonicAir Humidifier Pro, ensuring ideal humidity levels at any temperature.

G.A.S. make a version of this Humidity/VPD Controller which can be used with any mains powered Humidifier

Features
  • G.A.S - The leading and most innovative air control equipment manufacturer
  • Directly controls a G.A.S SonicAir Pro Humidifier for the ideal grow-room VPD
  • Doesn't need plugging into a wall socket; powered from the SonicAir Pro instead
  • 4 modes of operation gives the choice to control humidity or VPD, and to set either constant or separate day/night levels
  • 3 in 1 probe senses temperature, humidity and light (so it knows whether it is day or night)
  • Single control menu system makes setting up easy
  • 3 settings for VPD - Early Veg, Late Veg/Early Flowering, and Late Flowering
  • Set the growth stage and the controller works out the ideal VPD and controls the humidifier for you
How the G.A.S Intelligent Humidity Controller Works

The Intelligent Humidity/VPD Controller utilizes a 3-in-1 probe to detect temperature, humidity, and light levels within a grow space. It then manages a G.A.S SonicAir Pro Humidifier to adjust humidity to a user-defined level or automatically regulate Vapour Pressure Deficit (VPD) according to the growth stage and day/night cycle. With this model, the humidifier powers the controller through the connection cable, eliminating the need for a separate mains connection.

The controller offers four primary operation modes:

1. Relative Humidity 24 Hours: Maintains humidity at the user-set level continuously.

2. Relative Humidity Day/Relative Humidity Night: Allows separate humidity settings for day and night.

3. VPD 24 Hours: Automatically adjusts humidity to achieve the ideal VPD for the current temperature and growth stage.

3. VPD Day/Relative Humidity at Night: Regulates VPD during the day and switches to controlling relative humidity at night.

Mode 4 is recommended as it prioritizes VPD regulation during the day and relative humidity control at night, aligning with plant needs.

Note: While the G.A.S Humidity Controller effectively increases humidity, it doesn't lower humidity levels. However, pairing it with an adjustable dehumidifier alongside a humidifier pro can address high humidity levels when necessary.


 

You may also like:

€23.00
Sale
was €53 NOW €40.00
Out of stock
€525.00
Sale
was €268.00 NOW €240.00
© 2021 Growshop.ie web design by dmac media